CKR-606 Intermittent Pneumatic Compression

Brand:Flybear
Model:CKR-606D、CKR-606B、CKR-606A
Pressure Range:0-210mmHg
Treatment Time:5-99min
Intermittent Time:0-60s
Pressure maintenance in single chamber:0-12s
Operating Chambers:6

Product details

TypeCKR-606DCKR-606BCKR-606A
Working Mode

A1,A2,B1,B2,B3,B4,C1,C2,F1,F2,F3,F4

A1,A2,B1,B2,B4,C1,F1,F2

A1,B1,B4,C1

Pressure maintenance in 

single chamber

×

Individual pressure adjustment 

for each compartment

Automatic Pumping
Chamber OFF/ON
Mode Save/Reset
Touch Control
Parameter
  • Pressure Range:0-210mmHg

  • Treatment Time:5-99min

  • Rest time:0-60s

  • Pressure maintenance in single chamber:0-12s

  • Operation Chambers:6

Features
  • Integrated safety control system

  • 12 modes to meet more clinical treatment needs

  • Precise pressure control system

  • Automatic pumping to reduce the medical staff’s work

  • Durable airbags with incredible pressure resistance

  • Multiple working modes to meet more treatment needs

  • Airbag design with six sequentially stacked cavities

  • Ultra-quiet design

  • Pressure detection and promoting in real-time

  • Large display screen with touch control

  • Airbag leak detection

  • Saving prescriptions,convenient for clinical practice.

  • Four limbs can be treated at the same time

  • Emergency stop button to ensure patient safety and greatly reduce nursing workload

  • Individual pressure gradients and pressure periods can be adjusted for each chamber

  • Gradient pressure operation with a single click, convenient treatment and reduces the medical staff’s work

  • Single-chamber working mode to avoid wounds, indwelling needles, and other parts that are not suitable for extrusion

Working Mode

DescriptionPicture
A1

Starts to inflate from the first chamber, after the first chamber is inflated and deflated, the second chamber begins to inflate and deflate until the sixth chamber

CKR-606系列空气波压力治疗仪工作模式
A2

Starts to inflate every two chambers together from the first and second chambers. After the first and second chambers are inflated and deflated, the third and fourth chambers begin to inflate and deflate until the fifth and sixth chambers are inflated and deflated together.

B1

Starts to inflate from the first chamber, does not deflate after the first chamber is inflated, starts to inflate the second chamber, and deflates together after the sixth chamber is inflated

B2

Starts to inflate from the first chamber, does not deflate after the first chamber is inflated, starts to inflate the second chamber, and then inflates together until the sixth chamber is inflated (the pressure from the first chamber to the sixth chamber gradually decreases by 4%)

B3

Starts to inflate from the fourth chamber, and does not deflate after inflation. The fifth and sixth chambers are inflated in sequence and then deflated together. The third chamber begins to inflate but does not deflate. The fourth, fifth, and sixth chambers are inflated in turn. Deflate together after completion, inflate the second chamber, inflate but not deflate, and inflate the third, fourth, fifth, and sixth chambers in sequence and then deflate together, the first chamber begins to inflate, inflates but does not deflate, the second, The third, fourth, fifth, and sixth chambers are inflated in sequence and then deflated together

B4

Starts to inflate from the first chamber. After the first chamber is inflated, the second chamber is inflated. When the third chamber is inflated, the first chamber is inflated. When the sixth chamber is inflated, the fourth chamber is inflated. The fifth and sixth chambers are inflated and deflated at the same time

C1

Starts to inflate from the sixth chamber, after the sixth chamber is inflated and deflated, the fifth chamber begins to inflate and deflate until the first chamber

C2

Starts to inflate from the sixth and fifth chambers at the same time, after  deflated, the fourth and third chambers are inflated and deflated at the same time, then the second and first chambers are inflated and deflated at the same time

F1A1 and A2 mode combination, A2 mode is executed after A1 mode
F2A1 and B1 mode combination, execute B1 mode after A1 mode
F3A1 and C1 mode combination, execute C1 mode after A1 mode
F4A1 is combined with B1 and C1 modes. After A1 mode, B1 and C1 modes are executed in turn.